RXQ16BYM
    RXQ16BYM
    RXQ16BYM
    Product code: RXQ16BYM
    Brand:DAIKIN

    Key technical specifications RXQ16BYM

    • Model: RXQ16BYM

    • System type: VRV A – Cooling only

    • Refrigerant: R410a refrigerant – Environmentally friendly, high efficiency

    • Cooling capacity: 154,000 Btu/h (~ 45kW)

    • Power consumption: 12.6kW

    • Dimensions (Height x Width x Depth): 1,660 x 1,240 x 765 mm

    • Weight: 270 kg

    Share:
    Contact for advice
    Quotation: 0909326888
    Product out of stock

    VRV A Cooling-Only Outdoor Unit, R410a Refrigerant – Model RXQ16BYM | Capacity 154,000Btu/h

    VRV A Cooling-Only Outdoor Unit, R410a Refrigerant – Model RXQ16BYM | Capacity 154,000Btu/h

    RXQ16BYM product introduction

    VRV A cooling-only outdoor unit – Model: RXQ16BYM is a premium central air conditioning solution from a leading Japanese brand. With a cooling capacity of up to 154,000 Btu/h (equivalent to 45kW), the product is suitable for large commercial projects such as office buildings, hotels, shopping centres…

    RXQ16BYM key technical specifications

    • Model: RXQ16BYM

    • System type: VRV A – Cooling only

    • Refrigerant: R410a refrigerant – Environmentally friendly, high efficiency

    • Cooling capacity: 154,000 Btu/h (~ 45kW)

    • Power consumption: 12.6kW

    • Dimensions (Height x Width x Depth): 1,660 x 1,240 x 765 mm

    • Weight: 270 kg

    RXQ16BYM outstanding advantages

    • Energy savings with advanced inverter technology, helping reduce operating costs.

    • Stable operation in all weather conditions, ensuring effective cooling for large spaces.

    • Easy installation and maintenance, with a compact design that optimises installation space.

    • Environmentally friendly thanks to the use of R410a refrigerant, which does not deplete the ozone layer.

    RXQ16BYM practical applications

    The VRV A outdoor unit model RXQ16BYM is suitable for use in:

    • Company offices, administrative headquarters

    • Hotels, restaurants

    • Shopping centres, showrooms

    • Hospitals, schools

    Why choose Model RXQ16BYM?

    ✅ Powerful cooling performance
    ✅ Quiet operation, high durability
    ✅ Outstanding energy savings
    ✅ Reputable brand, official warranty


    Contact us now to receive the best quotation and advice on a VRV central air conditioning solution suited to your needs!

    🔧 TECHNICAL GUIDE TO INSTALLING THE VRV A OUTDOOR UNIT – MODEL RXQ16BYM

    1. 🧰 Preparation before installing RXQ16BYM

    a. Required tools and equipment:

    • Drill, welding machine, bolt-fastening tools

    • Pressure gauge, thermometer, clamp meter

    • Vacuum gauge (vacuum gauge)

    • Dedicated vacuum pump

    • R410a refrigerant for checking and topping up if necessary

    b. Check the installation site:

    • The base must be level and solid, not sloped, with a load-bearing capacity greater than 300kg

    • A well-ventilated location, protected from direct sunlight and heavy wind-driven rain

    • Minimum service clearances:

      • Front: ≥ 1,000mm

      • Rear: ≥ 300mm

      • Both sides: ≥ 300mm

      • Above: ≥ 1,000mm


    2. 📐 Mechanical installation of RXQ16BYM

    a. Outdoor unit dimensions:

    1,660 x 1,240 x 765 mm, weight 270kg

    b. Positioning and securing the base:

    • Use M10 or M12 bolts to secure the unit feet to the concrete plinth

    • The plinth must have a minimum height of 150mm above ground level to prevent flooding

    c. Ensure vibration reduction:

    • Use anti-vibration rubber mounts or vibration isolation pads under the unit feet


    3. 🔌 RXQ16BYM electrical installation

    a. Power supply:

    • 3-phase power 380V - 50Hz, supplied separately to each outdoor unit

    • Electrical cables must meet standards for heat resistance and current-carrying capacity above 20A

    b. Wiring:

    • Connect in the correct phase sequence L1-L2-L3 and earth according to the wiring diagram supplied with the unit

    • Check the fan rotation direction after powering on for the first time (if it rotates in reverse, swap 2 phase wires)

    c. Safety precautions:

    • Always disconnect the power before carrying out any work

    • Install a CB and surge protection in accordance with industrial electrical regulations


    4. 🔗 RXQ16BYM refrigerant piping installation

    a. Refrigerant piping:

    • Use copper pipes of the standard wall thickness for R410a, fully insulated

    • Ensure the piping has no kinks, dents or leaks

    • Maximum piping distance according to the manufacturer's recommendations (for example: 165m in length, 50m in elevation difference)

    b. Vacuum evacuation:

    • Evacuate the entire system for at least 30 minutes until the pressure reaches below -756mmHg

    • Check for tightness using a pressure gauge and test for leaks using soapy water

    c. Additional refrigerant charging (if required):

    • Calculate the refrigerant charge required based on the actual pipe length (for example: add x g of refrigerant/1m of piping beyond the standard length)

    d. Condensate piping:

    • Ensure a slope ≥ 1%

    • Install an additional water trap and strainer to prevent blockages


    5. ⚙️ RXQ16BYM startup and test operation

    1. Perform a final check of all electrical, refrigerant and drainage connections

    2. Switch on the power, start the system via the central controller

    3. Monitor:

      • Refrigerant suction and discharge pressures

      • Outdoor unit temperature, noise, vibration

      • Compressor load current

    4. Record operating parameters to compare with the manufacturer's standard parameters


    6. 🛠 Post-installation maintenance for RXQ16BYM

    • Clean the filters regularly every 3 months

    • Check refrigerant and operating pressure every 6 months

    • Service the entire system at least 1 time/year


    Do you need me to convert this article into a PDF file or print an installation technical checklist form for convenient use on site?

    Technical specifications

    Customer reviews

    5.0
    5
    0%
    4
    0%
    3
    0%
    2
    0%
    1
    0%

    Share your review of the product

    Ratings and reviews

      Sender information

      To submit a comment, please provide additional contact information
      Update
      • There are no products in the cart