Key Technical Specifications EWWH660VZSS
-
Cooling capacity: 658KW (cooling)
-
Energy efficiency (COP): 5.34W/W
-
Minimum cooling capacity: 20%
-
Power supply: 3 pha/400V/50Hz
-
Power consumption: 123KW (cooling)
-
Starting current: 188A (Cooling) / 268A (Max)
-
Number of compressors: 1 unit
-
Refrigerant charge (R1234(ze)/7): 145kg
-
Evaporator chilled water flow rate: 31.5 l/s
-
Evaporator connection pipe size: 168.3mm
-
Condenser cooling water flow rate: 38.1 l/s
-
Condenser connection pipe size: 219.1mm
-
Noise level: 105dB(A)
-
Unit dimensions (H×W×L): 2,292x1,233x3,690 mm
-
Net weight/operating weight: 3,451/3,611Kg
Daikin Chiller Model EWWH660VZSS – Outstanding Performance, Energy Savings
Chiller air conditioner Daikin EWWH660VZSS is one of today's leading industrial cooling solutions, delivering outstanding performance and optimal energy savings. With impressive technical specifications, this product is ideal for large-scale projects such as buildings, shopping centers, manufacturing plants, and industrial parks.
1. Key Technical Specifications of EWWH660VZSS
- Cooling capacity: 658 kW (cooling).
- COP: 5.34 W/W – ensures high energy efficiency.
- Minimum cooling capacity: 20% – adjusts flexibly to cooling load requirements.
- Power supply: 3 pha, 400V, 50Hz.
- Power consumption: 123 kW (cooling).
- Starting current Cooling/Max: 188/268 A.
- Number of compressors: 1 unit – optimized design minimizes wear.
- R1234(ze) refrigerant charge: 145 kg – environmentally friendly and compliant with international standards.
2. Superior Cooling Performance of EWWH660VZSS
- Evaporator chilled water flow rate: 31.5 l/s, ensuring fast and efficient cooling.
- Evaporator connection pipe size: 168.3 mm – helps optimize chilled water flow.
- Condenser cooling water flow rate: 38.1 l/s, ensuring superior heat rejection.
- Condenser connection pipe size: 219.1 mm – suitable for various heat rejection systems.
3. Durable Design, Easy Installation
- Unit dimensions: 2,292 x 1,233 x 3,690 mm – compact design saves space.
- Net/operating weight: 3,451/3,611 kg – ensures stability under all operating conditions.
- Noise level: 105 dB(A) – meets industrial standards and minimizes noise.
4. Key Advantages of Daikin EWWH660VZSS
- Energy savings: With a COP of 5.34 W/W, the product significantly reduces electricity costs.
- Environmentally friendly: Using R1234(ze) refrigerant, the product helps protect the ozone layer and reduce the greenhouse effect.
- High durability: High-quality compressor delivers stable operation over an extended period.
- Easy maintenance: Intelligent structural design reduces maintenance costs and repair time.
Practical Applications of the Daikin EWWH660VZSS Chiller Air Conditioner
Chiller air conditioner Daikin EWWH660VZSS is an ideal choice for large-scale industrial and commercial cooling needs. Common applications include:
1. Office Buildings and Shopping Centers
- Ensures stable air conditioning, maintaining a comfortable working environment for offices and customers in shopping centers.
- Saves energy through a high COP, significantly reducing operating costs.
2. Manufacturing Plants
- Cools industrial production lines, especially in industries requiring stable temperatures, such as food, beverages, and chemicals.
- Meets high cooling loads with its high capacity and ability to operate continuously.
3. Industrial Parks
- Used in central cooling systems in industrial parks.
- Easily integrates with modern heat rejection systems thanks to its flexible design and advanced technology.
4. Hospitals and Healthcare Facilities
- Provides a stable cooling supply for air-conditioning systems and medical equipment that require low temperatures.
- Low noise levels help ensure a quiet environment suitable for healthcare settings.
5. Data Centers
- Keeps servers and IT equipment operating reliably by maintaining an ideal temperature.
- Optimizes energy efficiency, reducing the risk of overheating and service interruptions.
6. Hotels and Resorts
- Provides cooling for guest rooms, lobbies, and amenities in upscale hotels and resorts.
- Saves installation space thanks to its compact design.
Benefits of Using the Daikin EWWH660VZSS Chiller Air Conditioner
- Energy savings: Suitable for projects requiring lower long-term operating costs.
- High durability: Operates reliably in harsh industrial environments.
- Flexible compatibility: Compatible with a wide range of cooling systems, from small to large.
With its outstanding performance and diverse applications, the Daikin EWWH660VZSS chiller air conditioner is a reliable choice that helps optimize costs and ensure long-term efficiency in every sector.
- Chiller air conditioner
- DAIKIN EWWH445VZSS
- cooling capacity
- energy savings
- R1234ze refrigerant
- industrial applications.
- DAIKIN chiller air conditioner
- high-capacity chiller
- energy-efficient chiller
- industrial air conditioner
- central cooling chiller
- high-efficiency chiller
- Daikin chiller air conditioner
- 512KW cooling capacity
- 5.22W/W COP efficiency
- industrial cooling
- central air-conditioning system
- R1234(ze) refrigerant
- EWWH660VZSS
Installation and Operation Guide for the Daikin EWWH660VZSS Chiller Air Conditioner
Proper installation and operation not only help the chiller air conditioner run efficiently but also extend the equipment's service life. The following are the basic steps for installing and operating the chiller Daikin EWWH660VZSS.
1. Preparation Before Installation
-
Check the installation area:
- Ensure the installation area is spacious enough and can support the unit's weight (at least 3,611 kg during operation).
- The foundation must be level and solid to prevent vibration.
- Ensure adequate clearance around the unit for maintenance and heat dissipation.
-
Check the power supply specifications:
- Confirm that the 3-phase, 400V, 50Hz power supply meets the unit's requirements.
- Install an electrical grounding system to ensure safety.
-
Check the included equipment:
- Ensure all accessories are present, including connection pipes, valves, pressure gauges, chilled water and cooling water pumps.
- Check the refrigerant (R1234ze) and water levels in the system.
2. Installing the Chiller Air Conditioner
-
Connect the piping:
- Evaporator: Connect the water supply pipe (168.3 mm) and the water outlet pipe in the correct flow direction.
- Condenser: Connect the cooling water supply pipe (219.1 mm) and the water outlet pipe.
- Ensure all connections are secure and leak-free.
-
Install the water pumps:
- Select pumps with suitable flow rates (31.5 l/s for the evaporator, 38.1 l/s for the condenser).
- Install a filter at the inlet to prevent debris from clogging the system.
-
Connect the power supply:
- Connect the power supply according to the manufacturer's wiring diagram.
- Check the connections, circuit breaker, and grounding system before switching on the power.
-
Check the system for leaks:
- Perform a pressure test to ensure there are no leaks in the piping system or compressor.
3. Chiller Air Conditioner Operating Guide
-
Initial startup:
- Check the entire system, including the power supply, pressure, water flow rate, and refrigerant.
- Switch on the power and start the compressor from the control panel.
-
Set operating parameters:
- Set the chilled water outlet temperature according to requirements (usually from 7°C – 12°C).
- Check operating parameters such as cooling capacity, current consumption, and pressure.
-
Monitor during the initial period:
- Observe the indicators on the control panel to ensure the unit is operating stably.
- Listen to the operating sounds to detect any abnormalities.
4. Periodic Maintenance and Inspection
-
Monthly maintenance:
- Clean the evaporator and condenser to remove scale and dust.
- Check the electrical system and ensure connections are not loose or burnt.
-
Annual maintenance:
- Check and replenish the refrigerant if necessary.
- Evaluate cooling performance and adjust the parameters.
-
Continuous monitoring:
- Ensure the noise level does not exceed 105 dB(A). If there is unusual noise, stop operation and inspect immediately.
Important Installation and Operating Notes
- Have installation and operation performed only by qualified, trained technicians.
- Do not adjust the parameters without instructions from the manufacturer.
- Always use genuine accessories to ensure safety and performance.
Following these instructions will make installation and operation of the chiller air conditioner Daikin EWWH660VZSS easier and more effective. Follow the procedures to get the most out of the equipment!
Technical specifications
Customer reviews
Share your product feedback
Ratings and reviewsRelated Products
EWWH940VZSS
EWWH860VZSS
EWWH770VZSS
ewwh550vzss
Fan Coil Unit Daikin
EWWH515VZSS
EWWH445VZSS