2FGN300HY1
    2FGN300HY1
    2FGN300HY1

    Technical Specifications: 2FGN300HY1

    • Model: 2FGN300HY1/RCN150HY19x2
    • Capacity: 30.000 BTU
    • Refrigerant type: R410A
    • Country of origin: Malaysia
    • Inverter technology: No
    • Warranty: 2 years for the entire unit, 5 years for the compressor
    Share:
    Contact for consultation
    Request a quotation: 0909326888
    Product out of stock

    Daikin Ceiling-Concealed Ducted Cooling-Only Air Conditioner Daikin 2FGN300HY1/RCN150HY19x2 - A Modern Cooling Solution for Your Space

    2FGN300HY1

    The Daikin 2FGN300HY1/RCN150HY19x2 ducted air conditioner is an ideal choice for spaces requiring an efficient, space-saving cooling system. With its ceiling-concealed design, the product offers a refined appearance suitable for various types of buildings, such as offices, hotels, or homes.

    Technical Specifications: 2FGN300HY1

    • Model: 2FGN300HY1/RCN150HY19x2
    • Capacity: 30.000 BTU
    • Refrigerant type: R410A
    • Country of origin: Malaysia
    • Inverter technology: No
    • Warranty: 2 years for the entire unit, 5 years for the compressor

    Product Advantages: 2FGN300HY1

    • High capacity 30.000 BTU, suitable for large spaces such as offices, meeting rooms, or commercial areas.
    • Ceiling-concealed design with a refined appearance that does not affect the interior space.
    • Uses R410A refrigerant for rapid cooling and energy savings.
    • Long-term warranty: A 2-year warranty for the entire unit and 5 years for the compressor, ensuring peace of mind throughout use.

    The Daikin 2FGN300HY1/RCN150HY19x2 air conditioner is an optimal solution for those seeking a combination of powerful cooling performance and elegant design, with easy installation and maintenance.

    Practical Applications of the Daikin 2FGN300HY1/RCN150HY19x2 Ducted Air Conditioner

    2FGN300HY1 - applications

    With its ceiling-concealed design and high capacity, the Daikin 2FGN300HY1/RCN150HY19x2 ducted air conditioner is an ideal choice for many practical applications in large spaces requiring efficient cooling and high aesthetic standards. Below are some practical applications of this product:

    1. Offices and High-Rise Buildings:

      • With a capacity of 30.000 BTU, the Daikin 2FGN300HY1/RCN150HY19x2 air conditioner can cool office spaces or high-rise buildings quickly and efficiently. Its ceiling-concealed design saves space and creates a professional, modern working environment without compromising aesthetics.
    2. Hotels and Resorts:

      • Hotels and resorts with conference rooms or large guest rooms can use the Daikin ducted air conditioning system to ensure effective air conditioning for a large number of guests, providing maximum comfort.
    3. Restaurants and Cafés:

      • This air conditioner is also well suited to restaurants and cafés with large spaces requiring rapid, even cooling. The product helps maintain a cool and comfortable environment for customers throughout their dining experience.
    4. Supermarkets and Shopping Centres:

      • With its ability to cool large spaces, the Daikin 2FGN300HY1/RCN150HY19x2 air conditioner is an ideal choice for supermarkets, shopping centres, or retail stores, where stable temperatures are needed to keep customers comfortable and preserve goods.
    5. Luxury Homes and Villas:

      • Spacious villas or luxury homes can also use this product to cool the entire space without compromising the aesthetics of the interior. Concealing the air conditioning system above the ceiling makes the space feel more open and modern.

    The Daikin 2FGN300HY1/RCN150HY19x2 ducted air conditioner not only delivers outstanding cooling performance but is also an ideal solution for spaces requiring high aesthetic standards, space savings, and easy installation.

    Detailed Guide to Installing and Operating the Daikin 2FGN300HY1/RCN150HY19x2 Ducted Air Conditioner

    Below is a detailed guide to installing and operating the Daikin 2FGN300HY1/RCN150HY19x2 ducted air conditioner. Installation requires professional technicians to ensure operating efficiency and safety.

    I. Installing the Daikin 2FGN300HY1/RCN150HY19x2 Ducted Air Conditioner

    1. Preparing the Installation Site:

      • Selecting the installation location: Choose a suitable concealed ceiling location for the indoor unit, with sufficient surrounding space for installation and maintenance. Ensure that the indoor unit is installed in a well-ventilated area free of obstructions.
      • Checking the ceiling structure: Ensure that the ceiling is strong enough to support the weight of the indoor unit and auxiliary components.
      • Outdoor unit location: The outdoor unit must be installed outdoors, away from areas with polluted air, dust, and direct sunlight.
    2. Installing the Indoor Unit:

      • Measure and mark the installation position for the indoor unit. The indoor unit must be installed at least 5cm from the ceiling to facilitate installation and maintenance.
      • Install the indoor unit suspension brackets at the prepared location.
      • Connect the copper refrigerant pipes (inlet and outlet refrigerant pipes) to the indoor unit. Ensure that the connections are tight and leak-free.
    3. Installing the Outdoor Unit:

      • The outdoor unit must be placed in a well-ventilated location with little dust and no obstacles blocking airflow.
      • Ensure that the outdoor unit is not exposed to heat sources or direct sunlight.
      • Connect the refrigerant pipes, electrical wiring, and drainage system from the indoor unit to the outdoor unit. Install the drain pipe from the indoor unit to the building's drainage system.
    4. Installing the Ductwork System:

      • Connect the ductwork system from the indoor unit to the areas requiring cooling. Ensure that the ducts are securely installed and leak-free.
      • Use suitable duct fittings to ensure that cool air is distributed evenly throughout the room.
    5. Electrical Connections:

      • Connect the electrical wires between the indoor and outdoor units, ensuring compliance with electrical safety standards.
      • Ensure that all connections are safe and free from short circuits or fire hazards.
    6. System Checks:

      • Recheck the copper pipe connections, electrical wiring, and ductwork to ensure there are no leaks.
      • Charge the system with R410A refrigerant if necessary, ensuring the correct refrigerant pressure.

    II. Operating the Daikin 2FGN300HY1/RCN150HY19x2 Ducted Air Conditioner

    1. Starting the Unit:

      • Switch on the power and turn on the remote control or the control panel on the indoor unit.
      • Select cooling mode (Cooling Mode) and set the desired temperature.
      • Ensure the air vents are unobstructed so that air can circulate freely.
    2. Adjusting the Temperature and Operating Mode:

      • Adjust the temperature as required, with an ideal temperature range of 24-26°C.
      • The air conditioner will automatically adjust the fan speed and airflow based on the selected cooling mode.
      • Check the cooling performance and ensure the indoor unit operates stably.
    3. Operating Other Functions:

      • Fan mode (Fan Mode): This mode uses only the fan without cooling, making it suitable for air circulation.
      • Dry mode (Dry Mode): Helps reduce humidity in the air without lowering the temperature too much.
      • Automatic mode (Auto Mode): The unit will automatically adjust the cooling parameters to suit the current room temperature.
    4. Regular Maintenance:

      • Clean the air filters regularly to ensure optimal cooling performance and extend the unit's service life.
      • Check the air duct system to ensure there are no blockages.
      • Regularly service the outdoor and indoor units, check the refrigerant level and recharge if necessary.

    III. Important Notes:

    • Electrical safety: Ensure all electrical connections are made correctly and check the circuit breakers to protect the unit.
    • Installation space: Ensure there is sufficient space around the air conditioner for air to circulate.
    • Energy-saving mode: If available, use energy-saving mode to reduce electricity costs.

    Proper installation and operation will help the Daikin 2FGN300HY1/RCN150HY19x2 air conditioner operate efficiently, providing a cool and comfortable space for users.

    Technical Specifications

    Customer Reviews

    5.0
    5
    0%
    4
    0%
    3
    0%
    2
    0%
    1
    0%

    Share Your Product Review

    Ratings and Reviews

      Related Products

      4FGN600HY1

      4FGN600HY1

      Price: Contact Us
      View Details
      4FGN500HY1

      4FGN500HY1

      Price: Contact Us
      View Details
      3FGN450HY1

      3FGN450HY1

      Price: Contact Us
      View Details
      4FGN400HY1

      4FGN400HY1

      Price: Contact Us
      View Details
      3FGN300HY1

      3FGN300HY1

      Price: Contact Us
      View Details
      2FGN250HY1

      2FGN250HY1

      Price: Contact Us
      View Details

      Sender Information

      Please provide additional contact information to submit a comment
      Update
      • There are no products in your cart